YourPaste - For your paste! Archive - Tools - Login

Posted by Mattie on Sun 24 Aug 2008 17:53 65 views - Syntax: None - Expires: never - Report - IMG - Download -

[root@s01 ~]# smartctl -a -d ata /dev/sda
smartctl version 5.36 [i686-redhat-linux-gnu] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Model Family:     Maxtor DiamondMax Plus 9 family
Device Model:     Maxtor 6Y160M0
Serial Number:    Y44Y6PXE
Firmware Version: YAR51HW0
User Capacity:    163,928,604,672 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   7
ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 0
Local Time is:    Sun Aug 24 17:52:51 2008 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 ( 302) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        No General Purpose Logging support.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  72) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  3 Spin_Up_Time            0x0027   195   194   063    Pre-fail  Always       -       14229
  4 Start_Stop_Count        0x0032   253   253   000    Old_age   Always       -       309
  5 Reallocated_Sector_Ct   0x0033   253   253   063    Pre-fail  Always       -       6
  6 Read_Channel_Margin     0x0001   253   253   100    Pre-fail  Offline      -       0
  7 Seek_Error_Rate         0x000a   253   252   000    Old_age   Always       -       0
  8 Seek_Time_Performance   0x0027   241   229   187    Pre-fail  Always       -       55973
  9 Power_On_Minutes        0x0032   227   227   000    Old_age   Always       -       378h+46m
 10 Spin_Retry_Count        0x002b   253   252   157    Pre-fail  Always       -       0
 11 Calibration_Retry_Count 0x002b   253   252   223    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   252   252   000    Old_age   Always       -       511
192 Power-Off_Retract_Count 0x0032   253   253   000    Old_age   Always       -       0
193 Load_Cycle_Count        0x0032   253   253   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0032   253   253   000    Old_age   Always       -       28
195 Hardware_ECC_Recovered  0x000a   253   251   000    Old_age   Always       -       2273
196 Reallocated_Event_Count 0x0008   253   253   000    Old_age   Offline      -       0
197 Current_Pending_Sector  0x0008   253   253   000    Old_age   Offline      -       0
198 Offline_Uncorrectable   0x0008   253   253   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0008   199   197   000    Old_age   Offline      -       2
200 Multi_Zone_Error_Rate   0x000a   253   252   000    Old_age   Always       -       0
201 Soft_Read_Error_Rate    0x000a   253   252   000    Old_age   Always       -       23
202 TA_Increase_Count       0x000a   253   252   000    Old_age   Always       -       0
203 Run_Out_Cancel          0x000b   253   252   180    Pre-fail  Always       -       0
204 Shock_Count_Write_Opern 0x000a   253   252   000    Old_age   Always       -       0
205 Shock_Rate_Write_Opern  0x000a   253   252   000    Old_age   Always       -       0
207 Spin_High_Current       0x002a   253   252   000    Old_age   Always       -       0
208 Spin_Buzz               0x002a   253   252   000    Old_age   Always       -       0
209 Offline_Seek_Performnce 0x0024   192   192   000    Old_age   Offline      -       0
 99 Unknown_Attribute       0x0004   253   253   000    Old_age   Offline      -       0
100 Unknown_Attribute       0x0004   253   253   000    Old_age   Offline      -       0
101 Unknown_Attribute       0x0004   253   253   000    Old_age   Offline      -       0

SMART Error Log Version: 1
ATA Error Count: 5
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 5 occurred at disk power-on lifetime: 5398 hours (224 days + 22 hours)
  When the command that caused the error occurred, the device was in an unknown state.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 00 df 81 97 e0  Error: ICRC, ABRT at LBA = 0x009781df = 9929183

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 df 81 97 e0 00      00:05:22.400  READ DMA EXT
  c8 00 20 3f 79 c1 e6 00      00:05:22.400  READ DMA
  c8 00 20 1f 79 c1 e6 00      00:05:22.400  READ DMA
  c8 00 08 17 79 c1 e6 00      00:05:22.400  READ DMA
  c8 00 40 d7 78 c1 e6 00      00:05:22.400  READ DMA

Error 4 occurred at disk power-on lifetime: 5393 hours (224 days + 17 hours)
  When the command that caused the error occurred, the device was in an unknown state.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 00 bf 1c 31 e0  Error: ICRC, ABRT at LBA = 0x00311cbf = 3218623

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 00 bf 1c 31 e0 00      00:44:36.768  READ DMA EXT
  25 00 80 3f 19 31 e0 00      00:44:36.752  READ DMA EXT
  25 00 00 3f 15 31 e0 00      00:44:36.752  READ DMA EXT
  25 00 80 bf 11 31 e0 00      00:44:36.736  READ DMA EXT
  c8 00 80 3f 11 31 ea 00      00:44:36.736  READ DMA

Error 3 occurred at disk power-on lifetime: 5391 hours (224 days + 15 hours)
  When the command that caused the error occurred, the device was in an unknown state.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 00 3f c1 16 e0  Error: ICRC, ABRT at LBA = 0x0016c13f = 1491263

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 00 3f c1 16 e0 00      00:15:15.792  READ DMA EXT
  c8 00 80 bf c0 16 e2 00      00:15:15.792  READ DMA
  25 00 00 bf bc 16 e0 00      00:15:15.776  READ DMA EXT
  25 00 80 3f bb 16 e0 00      00:15:15.776  READ DMA EXT
  25 00 00 3f b7 16 e0 00      00:15:15.776  READ DMA EXT

Error 2 occurred at disk power-on lifetime: 5391 hours (224 days + 15 hours)
  When the command that caused the error occurred, the device was in an unknown state.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 00 bf 6d a6 e0  Error: ICRC, ABRT at LBA = 0x00a66dbf = 10907071

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 80 bf 6d a6 e0 00      00:12:16.272  READ DMA EXT
  25 00 00 bf 69 a6 e0 00      00:12:16.272  READ DMA EXT
  25 00 00 bf 67 a6 e0 00      00:12:16.256  READ DMA EXT
  25 00 00 bf 63 a6 e0 00      00:12:16.256  READ DMA EXT
  25 00 00 bf 5f a6 e0 00      00:12:16.240  READ DMA EXT

Error 1 occurred at disk power-on lifetime: 5729 hours (238 days + 17 hours)
  When the command that caused the error occurred, the device was in an unknown state.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 0c 1a 07 9b e0  Error: UNC 12 sectors at LBA = 0x009b071a = 10159898

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 48 1a 07 9b e0 00  17d+07:00:26.976  READ DMA EXT
  25 00 20 fa 06 9b e0 00  17d+07:00:24.880  READ DMA EXT
  25 00 78 fa 70 9a e0 00  17d+07:00:24.880  READ DMA EXT
  25 00 08 42 9d 97 e0 00  17d+07:00:24.880  READ DMA EXT
  25 00 08 22 9d 97 e0 00  17d+07:00:24.880  READ DMA EXT

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%      7942         -
# 2  Extended offline    Completed without error       00%      7064         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
 

Comments


Name:
Comment:

© 2008 YourPaste.net - Disclaimer